When Solar Panels Are The Scapegoat For A Leaking Roof

roof leaks

Recently, at SolarQuotes, we hit a snag: Jono, our marketing guru, has been dodging drips from his ceiling in recent years, suspecting his solar setup might be the culprit. It was time for some detective work.

With two decades of roofing under my belt, I’ve seen it all: water sneaks in where you least expect, gravity be damned. In the coming weeks, we’ll dive into how and why this happens, solar panels or not. Kicking off with the quirks of iron roofs and the extra twists strata ownership brings.

Troubles With A Leaky Townhouse

Jono, like many Australians seeking affordability near the city, opted for a two-storey townhouse. However, typical of strata living, he owns the townhouse and solar panels but not the roof.

The Complaint

Jono faced an erratic drip leak; light rain barely mattered, but heavy downpours or sustained rainfall would inevitably bring water indoors.

He got a roofer out to see what was going on. This supposed expert only went up on the roof, and didn’t go inside the roof cavity (bloody amateur, if you ask me). Ultimately, he blamed the brackets used to fix the solar array.

lifted roofing nail

This nail has had some silicone sealant smeared on it, which appears to be acting as a funnel

Was Solar To Blame?

Armed with the best knowledge a plumber could offer, Jono rang SEM Group, his solar electrician, to get someone to check the installation. The system was under a workmanship warranty, and of course, Jono expected a good installer to stand by their handiwork.

SEM advised that if the problem were not due to the solar install, then a callout fee of $180 would apply.

inside a leaky roof

Roof purlin is going rotten because it’s continually being doused with water. Given a long downpour the water will make it through the roof and through the ceiling.

Solar Experts Found The Real Problem

The experts from SEM emphatically pointed to a raised roofing nail as the centre of the problem.

Inside the roof space, they could clearly see where the water had leaked in and discoloured the purlins.

Not all of this discolouration would indicate a leak from outside — you’ll see witness marks on the timber caused by condensation on the underside of the roof. However, from the photo above, it’s clear this leak has been ongoing for a long time and has started to rot the timber itself.

corrugated roof with ridge cap

On the right we see the ridge cap is ‘scribed’ so it follows the corrugated profile. Excellent work that’s undone by putting nails in the lower part of the flute, as seen on the left when the cap is removed.

Nailing The Problem

Roofing nails use a bellville washer to hold the iron tight to the roof. However, after a few years, the nail will pull out of the timber, and banging it back in with a hammer doesn’t help much.

What does work is replacing nails with screws, which stay tight and have a neoprene rubber seal. Nobody builds new houses with nails anymore, and indeed, you can’t use them on steel purlins.

It looks like somebody’s put some silicone sealant around the nail on Jono’s roof, but sealant doesn’t help when the nail simply pulls out of the timber again. What’s worse is that the sealant has formed a funnel, literally bringing more water in.

badly repaired roof

The red arrow indicates poor roofing practice. That nail shouldn’t be in the bottom of the flute and exposed. Obviously there has been silicone applied before, then a screw, and now more silicone snotted onto the same problem. If it were my roof, I’d throw the person who did this off of it.

Strata Shenanigans: Who Pays For A Leaky Roof?

This is where the challenges of a strata management company come into play. The company balked at paying the installer’s callout fee, arguing that while they might be responsible for the roof, Jono should bear responsibility for everything involved with the solar.

However, it was easy to prove that the roof was leaking, and that it had nothing to do with the solar array. So, in the end, the strata people had to send their own repairer to fix Jono’s roof — as well as another in the same complex that didn’t have solar.

leaky roof

A classic water stain on the lower side of a purlin. On the right, now the ridge cap is removed, we can see having the nail in the wrong part of the roof was the cause.

Pinpointing Leaks Isn’t Always So Easy

Intermittent roof leaks aren’t always easy to find, especially if sarking is involved. Having a secondary membrane under the roof can help prevent water and condensation from entering the building, but it can also divert water in curious ways.

Steel purlins can also be a trap because they tend to form a gutter. It’s not unheard of for purlins to carry water from a leak at one end of a building through to the other.

Water can leak through a poorly made penetration, or it can be windblown up underneath a flashing or valley, then it will wick down the underside of the cladding, travel along a purlin and run down a rafter.

The route is often devious, and getting somebody inside the roof space to watch it happen during a downpour can obviously be pretty tricky.

badly made flashing

This was a brand new roof, ruined by one of the idiots I worked with. He sealed the conduit alright, then made four leaks in the roof with screws in the down flutes.

Silicon sealant and rubber flashings have largely removed the craft from waterproofing. And sadly, a lot of trades don’t think much about how to make something fundamentally waterproof, relying instead on the catch cry: “Do your best and silicon the rest”.
One of the worst I diagnosed was from a poorly installed solar power system using novel framing on a curved roof. They’d driven screws through the bottom of the corrugated roof profile, meaning it wasn’t mechanically waterproof but relied on silicone sealant.

That water traversed some nine metres of purlin, before dripping straight into a laptop PC. A silly mistake and an expensive lesson for all concerned.

water leak from solar array

Dam building is dumb

What To Do If You Spring A Leak

Roof leaks can be frustrating to find. Trust me, I have been in the roof with a customer hosing water from the outside.

I’ve even had a customer with a new house cut a second access hole into the ceiling space, as it was the only way he could poke his head up as soon as a rainstorm hit.

Sometimes, leaks are caused by substandard solar installations. But, as in Jono’s case, often a solar array is a red herring in the investigation; an easy scapegoat.

So, when you’re getting solar, I can’t understate the value of quality workmanship from a well-established company.

Jono’s issue was relatively easy to diagnose and someone else’s problem to fix. You might not be so lucky.

About Anthony Bennett

Anthony joined the SolarQuotes team in 2022. He’s a licensed electrician, builder, roofer and solar installer who for 14 years did jobs all over SA - residential, commercial, on-grid and off-grid. A true enthusiast with a skillset the typical solar installer might not have, his blogs are typically deep dives that draw on his decades of experience in the industry to educate and entertain. Read Anthony's full bio.

Comments

  1. Roof was nearly flat – with slight fall to the problem area. Yes, I know. That’s a bit iffy but it’s to code, and was intended to host lotsa North Facing strings/panels.

    Found the screws at the very end oof the rails – closest to the gutter – were over-tightened. This caused the new Colorbond to deflect *up* at the outside edge – forming a slight angle back into the timbers behind the gutter/in the wall.

    This meant water flowed back into the wall – instead of out into gutter.. Particularly in NE winds.. Lots..

    The walls were new/well insulated with aircell (which hides water really well) and took to water down to a steel beam, and then out along LVL for vast flat ceiling downstairs.

    Eventually water would find exits ~everywhere, including downlight holes – across this huge flat area. It coul;d have been anything/two levels down.

    One overnight stream found a laptop – on table below. Bingo!

    Couldn’t get to the culprit because panels went all the way to the edge, and I’m not that skinny/crazy. A very tall ladder and lots of squinting fixed it – then sealed the length – in case any others were crushed ~back.

    ~12 wet/dry mths finding problem. Half a day and bucket of Sikaflex FC fixed it for keeps/8yrs ago.

    Grmpy? Moi?

  2. David Issko says

    I’m confused about the roofer. Did he not show proof that the solar installation was the culprit? How did he come to that conclusion anyway?

    Did he refund Jono due to his amateur mistake and laziness? I hope Jono gave the roofer a bad Google rating.

  3. In my experience the biggest clue to help find those annoying little leaks is capillary action.
    I remember one job where the solar rail bracket was screwed down so tight on the corrugated sheet which happened to be on the side lap and it squashed the lap together so tight that the capillary action was able to work right across to the edge of the underside lap.

  4. George Muscat says

    Everytime someone is on a roof or manipulating it; there is a real risk of a roof leak.

    I purchased 20 cement roof tiles for my solar installer, just incase they broke any. They broke about 5 of them as I expected.

    About a week later the roof leaked. Took photos from within the roof cavity showing light coming through a cracked tile.

    Installer claimed “that running water caused the tile to crack.” Really? So the roof tile isn’t designed to flow water? Come on please, be realistic.

    It more the attitude of some people to deflect blame, rather than fix the problem they were in all likelihood to have caused.

  5. I have had the challenge of being called out many times to find leaks.
    My most difficult that I found was one where the water did FIVE 90 degree turns before finding it’s way through the bathroom ceiling … the suspected evaporative cooler above it was found innocent.
    My parents had a minor leak. Despite many inspections on the roof and in the cavity and lots of silicon “just in case” we never did find that leak … but the leak stopped when the evaporative was removed.
    In my current home a minor leak was found to be the sarking mashed and not refixed by an air-con installer, so all the condensation from above dripped onto the plaster ceiling.

  6. Where should the screws for the dektite be placed for solar penetration on colorbond? I’ve seen them placed on the side (not top) of the colorbond profile (4 screws total) which I presume is the gold standard approach as well as siliconing the penetration, dektite and screws on top of dektite?

    • Anthony Bennett says

      Hi Sam,

      Penetrations are an art unto themselves and the subject of an entire post which is currently in the works.

      Best practice is always to remain mechanically waterproof, screws should be in the top of the profile.

Speak Your Mind

Please keep the SolarQuotes blog constructive and useful with these 5 rules:

1. Real names are preferred - you should be happy to put your name to your comments.
2. Put down your weapons.
3. Assume positive intention.
4. If you are in the solar industry - try to get to the truth, not the sale.
5. Please stay on topic.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Get the latest solar, battery and EV charger news straight to your inbox every Tuesday