Solar installers have a love hate relationship with the Australian standards. But with this week’s update of the solar inverter standard AS4777.1 there’s reasons to celebrate. Read on as I explain how raising the residential solar voltage limit to 1000 Volts DC helps put more solar on your roof and more AC power into your switchboard.
The first solar inverter I put on my house was a Latronics PVE 2500. Made in Queensland, it was notorious for being both reliable and inflexible. A single phase machine, with a single MPPT and maximum input of only 206 volts, it was a simple product for a simpler time.
Progress means inverter suppliers now offer wide operating windows but until AS4777 was updated, we couldn’t take full advantage.
In 2021 Australian installers & suppliers were cock-a-hoop when AS5033 (solar arrays) was updated to allow 1000V arrays. The happiness was short lived though. When some pedant pointed out AS/NZS 4777.1:2016 didn’t agree, there was much dismay.
The previous version of 4777.1 had an unnecessary mention of voltage, which limits grid connected inverter systems to 600V, creating a ludicrous situation where 1000V domestic systems were allowed but only if they were off-grid.
Now standards are harmonised they refer to, but don’t interfere with each other. And we can get on with installing more solar!
What Is Voltage, Anyway?
Solar panels are made up of many small cells that generate electricity. Producing about half a volt each, they’re connected in series to increase the output to a useful level. For example, 10 cells might be enough to charge a phone with 5volts, but for a practical panel we use 54, 60, 72, 96 or many more cells. Then to power your house, many more panels are connected together.
Think of it like water flowing through a pipe. The higher the voltage, the more “pressure” is in the system. With the old rules, we couldn’t put too many panels in series because the voltage would get too high.
The job of your inverter is to smooth this variable voltage Direct Current (DC) supply, into a steady 230V Alternating Current (AC) synchronised for use in your house.
Why 600 Volts Continues As The Norm
Most solar systems use panels connected in series to generate up to 600 volts DC. You can approach this threshold, but exceeding it can blow the inverter up.
The system design must consider your address because cold localities mean the voltage could rise well above the module’s sticker rating of say, 38Volts, so it’s not just a matter of dividing 600 by 38 for XX panels.
For your run of the mill single phase system, this rule change isn’t going to mean much. Electrically, it’s not hard to fully load a 5 or 6kW inverter with a couple of strings under 600 volts. The Fronius Primo 8.2 is the only unit I readily recall as single-phase and 1000-volt input.
Why 1000 Volts Is Better
It’s actually a matter of inverter topology. Anything is possible but inside the box it’s easy to convert sub 600VDC to 230VAC, whereas 1000VDC is more efficient when you want 400VAC output for 3 phase.
With the new 1000-volt limit, we can connect more panels. For example, using nominal 38-volt panels, we could only use about 14 in series under the 600V ceiling, but now up to 24 panels are possible. This means we can generate more power from the same circuit, which is electrically more efficient, plus saves money, time and materials.
Higher voltage means every day the inverter starts earlier, finishes later and creates less waste heat.
Commercial Solar Is Already 1000Volt
If you’ve seen solar installations on schools or other large buildings, you may notice the inverters are in cages. This security measure isn’t for theft but is called up in the standard as “restricted access.” You’re not allowed to fiddle with it unless you have a tool for access.
Domestic buildings (as defined in the building code) were excluded but the solar industry rule of thumb was that if you slept inside, it couldn’t be 1000VDC. Unless it was a nursing home.1
How Big Systems Benefit
As solar prices plummeted and large systems became much more feasible, we ran into problems.
3 Phase inverters designed for 1000V input couldn’t be “filled up” without exceeding 600VDC, so large systems on large homes became expensive when you had to buy two or more inverters to be able to cover all the roof space and remain under the artificial ceiling.
The only advantage was having more MPPT inputs to cope with complex roof shapes and a good excuse to install a battery backed hybrid.
Wattage For Winners
If you have 3 Phase (or you’re looking to upgrade) these new rules are a boon. Get yourself some quotes and get as much solar as you can fit on the roof.
- The only consistent complaint I’ve ever had in 15 years doing solar is this; “I wish we’d installed more.”
- Systems get cheaper as they get bigger (in dollars per watt terms)
- Your consumption becomes a smaller part of the yield
- For any given hour, you can convert whatever sunlight is available into useful energy, especially at the ends of the day when the electricity is most valuable under TOU pricing.
I wholly recommend large solar systems and 1000VDC now offers flexibility to achieve that.
Tune in next time, I’ll explain more about 1000 volt systems with actual numbers. Plus, the other exciting2 changes with AS4777:2024
Footnotes
- As an aside, I’ve spent a lot of time doing solar in aged care homes. Those places are depressingly quiet and beige; they desperately need to be combined with child care centres. We owe it to the old people who need the company, and the young ones who need the wisdom. ↩
- really we have been dying for this update to come out ↩
I’ve made some short “Tech Quickie” videos explaining the changes and posted on YouTube:
Also ability to put inverter a long way from panels. At 1000vdc @15 amps 4mm2 solar cable would only drop 3 volts over 200m. Nice change to rules
Actually voltage drop with 4 mm2 cable and 15 A current = 30 V over 200 m.
I stand corrected. I was looking at 3% in voltage drop field and wrote 3 volts drop .
Interested to hear your thoughts on new legislation planned for solar exports in QLD in July 2025. There doesn’t seem to be any clear information regarding the new sun tax.
Q?1 Is the proposed 1.2 – 1.5 cents per kWh tax deducted from your scheduled FIT?
Q?2 Is the tax applied to any export above the cap, or to all exports within peak production?
Q?3 Will larger system upgrades be effectively penalised, with high exports and the new tax?
Seems to me that we are being coerced to adopt battery storage when at this point it makes no economic sense to do so.
As far as I’m aware the cents per kWh for the proposed 2 way tariff in QLD has not been released. If you have a link please let us know!
If it works like Ausgrid’s it will reduce your Feed In Tariff in the middle of the day and increase it later in the day.
I believe, if you choose to enrol in flexible exports, you don’t have to pay the export charge.
You can see what the impact will be on you – assuming the pricing is similar to Ausgrid’s – with our sun tax calculator.
Most people are looking at $10-30 per year increase in their bills if they become subject to this charge.
I think the Fronius charts show that it is marginally more efficient at 610V than 800V.
The improvements to production starting earlier and finishing later, and fewer strings meaning lower I²R losses are all great. A very welcome change!
Hello Anthony,
I believe the increased residential DC voltage limit is stated in CL4.1b) for PV arrays and not CL4.3.2.
Thanks Anthony, nice footnote #1, have you suggested it to planning depts.?
I say they should be located together above shopping malls so that the elderly can pop down for a spot of shopping and socialising without having to get on a bus and parents can do their shopping before or after picking up the children without another stop.
Why should we isolate our aged ones from the society they created?
Hi Michael,
I get your point but six straight weeks of christmas musak would probably have me throwing myself off the roof. Seeing as we apparently bow down at the altar of the consumer economy, I guess Sunday trading is now the social centre. Sadly we buy Thomas the Tank Engine toys to help reinforce the notion that kids need to be “very useful engines” while the economy relies on fast fashion & endless plastic crap to keep the wheels turning.
We’d be better off with a library, tool exchange, bowling green, mens shed, meals on wheels kitchen & a repair cafe. Rampant consumerism doesn’t help anyone.
Anything would be better than the current treatment we mete out to our elders. Despite the Royal Commission, the LNP are demanding that proposed aged care reforms do not include criminal penalties and gaol time for abusers in aged care. Imagine the uproar if child abuse didn’t attract criminal charges..?
At least solar is good news for all concerned. It would be great if I could get some old retired technician to repair solar inverters though…
so this suggests that my ground mount with 20 panels in two strings could now be combined in to one series string to allow more panels to be attached to the now unused 4mm2 pair – obviously with the appropriate new inverter
Hi Andrew,
Yes. We’ve got an article coming to explain this further. Stay tuned.
Cheers
Probably a silly question, does this impact in any way the inverter limit of 75% of total panel wattage (assuming no batteries, etc)?
Hi Esp,
I’m afraid the “133% rule” still applies sadly
Methinks that this statement:
‘The job of your inverter is to smooth this variable voltage Direct Current (DC) supply, into a steady 230V Alternating Current (AC) synchronised for use in your house’ could be described better as:
The job of your inverter is to convert the smooth DC supply from your panels into 230VAC that resembles, as closely as possible, the pure sine wave AC that alternators provide, for use in your house.
Just saying
1. If any single phase inverter has the input voltage of 1000v is it compatible with the amendment.
2. After the amendment if we install 600v input voltage inverter is it ok.
Hi James,
Yes and yes.
Will inverter input design need to change if the incoming voltage increases from 600 VDC to 1 000 VDC (eg additional component spacing to prevent flashover)?
If so, is there only a limited set of inverters that a compatible with the higher input voltage?
Many 3ph inverters are already designed for 1000vdc and we have for years been using them in Australia on commercial jobs.
The new standard means 1000vdc is legal on a dwelling.
Are the networks now accepting connection requests conforming to the 2024 standards?
Do the different networks adopt the standard at different times?
Does anyone know when the new 1000V regulation is allowed for new solar installations?
Right now Kiwi,
There’s a grace period where you can use the old standard or the new one… but not a mix of both.